Where pressure accuracy matters
Charge pressure matters: Mobile fire suppression systems are charged to a specified pressure based on ambient temperature. The measurement instrument needs to let the technician set that pressure accurately.
Small margins can have large consequences: As temperature falls, system pressure can fall with it. An inaccurately charged system can have less margin before the low-cylinder-pressure alarm threshold is reached.
Analogue readability adds uncertainty: A conventional dial requires the technician to judge needle position. Digital indication provides the measured value directly, while a correctly selected range can substantially reduce measurement uncertainty.

The solution
Match the gauge range to the pressure you need to set
For mobile fire suppression systems, accurate charging starts with selecting a gauge range suited to the specified system pressure. Many systems operate around 1,350–1,750 kPa, where a broad-range analogue gauge can introduce more measurement uncertainty than the charging procedure requires.
A correctly ranged digital gauge provides a direct numerical reading without estimating needle position. Depending on the system pressure, a lower-range DM80 can be selected closer to the required charging pressure, while its specified overpressure capability provides protection against pressure excursions beyond the measurement range.
The result is greater confidence that the system has been charged to the pressure specified by the manufacturer’s temperature/pressure chart. For fire sprinkler systems, the same digital platform provides clear pressure measurement for testing and servicing.
Best fit for fire work
More accurate charging starts with the right gauge range
For mobile fire suppression systems, select the digital gauge range around the pressure specified by the manufacturer’s temperature/pressure charge chart. A direct numerical reading removes analogue needle interpretation and gives the technician greater confidence in the pressure being set.
For many systems charged around 1,350–1,750 kPa, a correctly selected lower-range digital gauge can substantially reduce measurement uncertainty compared with a broad-range analogue gauge.
Recommended: DM80 M / DM80 M UMS · Configuration: Service kit · Best for: Charging, servicing and field pressure checks
Clear digital pressure measurement for sprinkler system testing
For sprinkler system testing and servicing, digital indication provides a clear numerical pressure reading without analogue needle interpretation. Select the pressure range according to the system, test procedure and required measurement range.
Recommended: DM80 M · Configuration: Gauge or service kit · Pressure range: Confirm against the required sprinkler testing application
Also in the range
DM80 M: Digital pressure gauge
For technicians who already have the required charging hose, adaptors and test fittings. Select the pressure range to suit the system pressure being measured.
DM80 M UMS: USB data-logging pressure gauge
Adds USB data logging where pressure readings need to be captured and retained, while providing the same direct digital indication for system charging and pressure checks.
Applications
Fire pressure testing applications
Fire sprinkler systems
Clear digital pressure measurement for sprinkler system testing, servicing and pressure checks.
Mobile fire suppression systems
Accurate system charging against manufacturer temperature/pressure charts, plus portable pressure testing, diagnostics and field servicing.
Fire pump testing & commissioning
Digital pressure measurement during pump testing, commissioning and system pressure checks.
Hydrant & booster systems
Clear pressure measurement during hydrant and booster system testing, servicing and commissioning.
Options at a glance
Low · Mid · High: with or without the kit
For fire applications
Sprinkler systems → Select the gauge range according to the required test pressure, system procedure and measurement range.
Mobile fire suppression → Select the gauge range around the manufacturer’s specified charge pressure; DM80 M or DM80 M UMS service kits provide the complete setup for charging, servicing and field pressure checks.
Specifications from Leitenberger datasheets rev. 08/2026. Welded stainless-steel measuring cell (no gasket in the pressure path) and made in Germany: all tiers. 100 million pressure cycles minimum (DM80 ML and M).
Resource centre
Fire pressure testing resources
Digital pressure gauges for fire sprinkler system testing
How digital pressure measurement supports clear readings during sprinkler system testing, servicing and pressure checks.
Charging mobile fire suppression systems accurately
How charge charts, ambient temperature, gauge range and measurement accuracy affect the pressure set during mobile fire suppression servicing.
Why calibration certificates matter in fire system testing
Understanding calibration documentation, serial-number traceability and where measurement evidence becomes important.
Digital vs analogue pressure gauges for mobile fire suppression
How gauge accuracy, full-scale range and analogue needle readability can affect the pressure a technician actually sets.
Validate it for your compliance work
Tell us the standard you test to and we’ll confirm range, certification and suitability first.
What happens next
Send the form
Our sales team reviews it
We email or phone you back